Technical Data |
|
| The standard measuring value inputs of the DLx MET | • 16 bit Counter for all THIES anemometers |
| Further Thies sensors connectable to the RS485 bus | • THIES Laser precipitation monitor LPM • THIES-Ultrasonic-Anemometer 2D / 3D • THIES-Sensor-Interface with 6 or 9 additional channels |
| A/D converter RTC real time clock DCF 77 radio clock |
max. 24 bit resolution with differential inputs with automatic leap year detection optional DCF77-antenna for automatic time synchronization |
| Measuring cycle | Selectable 1 second … 60 minutes |
Storing cycle |
1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 min like mean values, 2 h, 3 h, 4 h, and 6 h are additionally selectable for ex. from 10 sensors and 10 minutes mean values as well as 1 h extreme values follows a storing capacity of approx. 288 days. |
Power supply |
12 V / 7 Ah voltage control 12 V / 20 W max. directly connectable Lithium cell for buffering of data and clock 115 / 230 V, 100 VA controlled status of power supply selectable via firmware in intervals from 1 ... 30 seconds |
| Operating temperature Housing Protection |
-30 ... +60 °C Stainless steel IP 65 |
Please contact us for your individual requirements. We are happy to advise you. |
|
radiation etc.).