Wind
Direction-dependent |

Digital-
Analog-Transducer TWThe pulses from wind sensor 4.3308.10.000 are converted by the measuring transducer into standardized analogue output signals. These output signals are available:
Moreover, the following settings can be effected through the coding switch:
| Order Code | Technical Data | ||
| 4.3348.XX.XXX | Characteristic | Description | |
| .00. | Model | wall mounting case | |
| .10. | PC-board | ||
| .040 | Electr. output | 0 - 20 mA (max. 600 Ohm) | |
| .041 | 4 - 20 mA (max. 600 Ohm) | ||
| .060 | 0 - 1 V (max. 10 mA) | ||
| .061 | 0 - 10 V (max. 10 mA) | ||
| Measuring value | mean value | ||
| Measuring
range codable |
6
values up to 50 m/s, 5; 10; 20; 30; 40; 50 m/s |
||
| Time of integration codable | 24; 48; 120; 240 s | ||
| Relays-delay | codable, 1,5 ... 45s | ||
| Relay-load | max. 200 W / 230V / 8A | ||
| Electr. input | 2 x 15 V pulse | ||
| Operating voltage | 230 V / 50 Hz | ||
| Ambient temp. | 0 ... +40°C | ||
| Protection | IP 65 (wall mounting case) | ||
| Dimensions | wall mounting case | 200 x 120 x 75 mm | |
| PC-board | 170 x 100 x 30 mm | ||
| Weight | wall mounting case | 0,65 kg | |
| PC-board | 0,25 kg | ||
|
|
|||