Thies Clima
Wind
Wind
Direction-dependent
   

Wall mounting caseDigital- Analog-Transducer TWDigital- Analog-Transducer TW
mean value

The pulses from wind sensor 4.3308.10.000 are converted by the measuring transducer into standardized analogue output signals. These output signals are available:

  1. as direction-dependent or
  2. as direction-independent value.

Moreover, the following settings can be effected through the coding switch:

 
Order Code Technical Data
4.3348.XX.XXX Characteristic Description
.00. Model wall mounting case
.10. PC-board
.040 Electr. output 0 - 20 mA (max. 600 Ohm)
.041 4 - 20 mA (max. 600 Ohm)
.060 0 - 1 V (max. 10 mA)
.061 0 - 10 V (max. 10 mA)
Measuring value mean value
Measuring range
codable
6 values up to 50 m/s,
5; 10; 20; 30; 40; 50 m/s
Time of integration codable 24; 48; 120; 240 s
Relays-delay codable, 1,5 ... 45s
Relay-load max. 200 W / 230V / 8A
Electr. input 2 x 15 V pulse
Operating voltage 230 V / 50 Hz
Ambient temp. 0 ... +40°C
Protection IP 65 (wall mounting case)
Dimensions wall mounting case 200 x 120 x 75 mm
PC-board 170 x 100 x 30 mm
Weight wall mounting case 0,65 kg
PC-board 0,25 kg

Info requestInfo request HomeHome