Pressure |
| Electrical Transmitter | |
Baro Transmitter
An electrical transmitter which indicates directly the measured values of the atmospheric air pressure. The measured value is indicated and delivered as electrical resistance value.
| Order No. |
Technical Data
|
![]() |
||
|---|---|---|---|---|
| 3.1150.10.015 | Measuring range | 946 ... 1053 hPa | ||
| Scale graduation | 1 hPa | |||
| Accuracy | ± 1.5 % of mr. | |||
| Electr. output | 0 ... 200 Ohm | |||
| Above sea level | max. 3000 m | |||
| Meas. element | Aneroid capsules, temperature compensated | |||
| Ambient temp. | -20 ... +60 °C | |||
| Case material | Synthetic | |||
| Cable | 1 m, LiYCY 5 x 0.5 mm² | |||
| Dimension | 122 x 120 x 85 mm | |||
| Weight | 0.75 kg | |||
Barotransmitter PTB100A, Barotransmitter PTB100B
Barotransmitters measure the barometric ambient pressure and emit the measured value as an electrical voltage value. Owing to its low current consumption, It is particularly suitable for use in combination with data loggers. To be mounted preferably in data logger systems.
| Order No. | Technical Data | ![]() |
||
|---|---|---|---|---|
| 3.1158.00.073 | Measuring range | 800 ... 1060 hPa | ||
| 3.1158.10.073 | 600 ... 1060 hPa | |||
| PTB100A | Accuracy (20°C) | ±0,3 hPa | ||
| Linearity | ±0,25 hPa | |||
| PTB100B | Accuracy (20°C) | ±0,5 hPa | ||
| Linearität | ±0,45 hPa | |||
| Resolution | 0,1 hPa | |||
| Hysterese | ±0,03 hPa | |||
| Electr. output | 0 ... 5 V DC | |||
| Operating voltage | 10 - 30 VDC (< 4 mA) | |||
| Ambient temp. | -40 ... +60°C | |||
| Dimension | 59 x 88 x 21 mm | |||
| Weight | 0,09 kg | |||
Digital Barotransmitter
Indicating measurement instrument with analogue output to determine the atmospheric pressure. An aneroid capsule with inductive displacement pickup serves as a sensor. The sensor signal is amplified electronically and displayed on a LC display. The analogue output is available for the connection of electronic recording and control instruments. Behind the removable front panel there is a potentiometer to reduce the measured value to sea level. The instrument is in the form of a switch cabinet for panel installation.
| Order No. | Technical Data | ![]() |
||
|---|---|---|---|---|
| 3.1159.00.040 | Electr. output | 0...20 mA | ||
| .041 | 4...20 mA | |||
| Measuring range | 913.3...1113.3 hPa | |||
| Accuracy | ± 0.5 hPa (at NN) | |||
| Resolution | 0.1 hPa | |||
| Display | 4½-digit, LED red | |||
| Temp. range | 0...+ 50°C | |||
| Above sea level | 0...850 m | |||
| Operating voltage | 230 V / 50 Hz | |||
| Dimension | 96 x 96 x 125 mm | |||
| Weight | 0.6 kg | |||