Wind |
The
wind direction transmitter serves for the detection of the horizontal wind direction
in the field of meteorology and the technology of environmental protection.
Special characteristics:
Mode of Operation
The
dynamic characteristics of the wind vane is achieved by the aluminium light-weight
construction. The co-action of wind vane and balance weight results in a high
damping ratio with small delay distance as excellent characteristic of the complete
vane.
The axis of the wind vane is running in ball bearings, and is coupled, in contactless
magnetic manner, with the axis of the integrated potentiometer. Thus, clearance
and friction in the coupling are avoided, and an easy starting is guaranteed.
An AC- or DC-voltage of 24 V is intended for the separate supply of the optional
heating. In all probability, the heating guarantees a trouble-free function
of the Wind Direction Transmitter First Class even under extreme meteorological
icing-conditions.
The outer parts of the instrument are made of corrosion-resistant anodised aluminium,
and stainless steel. Highly effective labyrinth gaskets and O-rings protect
the sensitive parts inside the instrument against humidity and dust.
| Order- No. | 4.3150.00.110 | 4.3150.10.110 |
| with Heating | without Heating |
Technical Data:
|
Characteristic
|
Description
|
||
|---|---|---|---|
| Measuring Range | 0 ... 360 ° | ||
| Measuring Accuracy | 0,25% (1°) | ||
| Survival speed | 85 m/s up to 0,5 h (without damages) | ||
| Permissible ambient conditions for operation | -50 ... +80°C all occurring situations of rel. humidity incl. dew moistening | ||
| Electrical output | Potentiometer
10k An electronic protective circuit avoids an overloading of the potentiometer in case of erroneous connection, and on transition from 0° to 360 °. The protective circuit represents a multiplier of 500 ohms, however it limits the short-circuit-current on transition from 0° to 360 ° (and vice versa) to < 2,5 mA. |
||
| Linearity | 0,25% (1°) | ||
| Starting threshold | < 0,5 m/s at 10° amplitude | ||
| Delay distance | < 1 m (acc. to D 53666 – 96) | ||
| Damping ratio | D > 0,25 (acc. to ASTM D 53666 – 96) | ||
| Quality factor | ![]() |
||
| Heating | Surface
temperature of housing neck > 0 °C at 20 m/s up to –10 °C air temperature,
at 10 m/s up to –20 °C using the Thies icing standard 012002 on the housing
neck heating regulated with temperature sensor |
||
| Electrical supply for Potentiometer | voltage:
4V DC to 42 V DC (galvanic isolation from the housing) Strom: < 2,5 mA on transition from 0 - 360° and 360 - 0° multiplier: 500 Ohm (representative) |
||
| Electrical supply for heating | voltage: 24 V AC/DC (galvanic isolation from the housing) | ||
| Capacity: 25W | |||
| Connection | 8-pole plug connection for shielded cable in the shaft | ||
| Montage | Mounting on mast 1“, for ex. DIN 2441 1½ “ with separate adaptor (option) | ||
| Weight | ca. 0,7 kg | ||
| Protection | IP 55 (DIN 40050) | ||
| EMC | EN
61000-6-2:2001 (immunity) EN 55022:2001, Class B (interfering transmission) |
||