About Thies ClimaNiederschlag Precipitation

 


Precipitation  Transmitter, OmbrometerPrecipitation Transmitter

The instrument is designed to measure the height, quantity and the intensity of the precipitation striking the surface of the earth. The measuring principle, tipping bucket, is basing on the description "Guide to Meteorological Instruments No 8" of the WMO (World Meteorological Organization). The precipitation, collected by the collecting surface and the collecting funnel, is conducted into a tipping-bucket. The tipping bucket consists of two bucket-compartments. Is one of these compartments filled with water it tips over, and the water drains off. Meanwhile subsequent rain falls into the newly positioned upper compartment. The tipping movement is detected by a Reed-contactor, and a connected electronics, and produces a respective output signal.

There are two outputs available:
1. Analogue output for the output of the precipitation sum as voltage- or current value.
2. Pulse output for the output of single precipitation meter pulse.

The electronics of the precipitation transmitter is equipped with a linearising system. The linearising procedure is basing on a precipitation-/intensity-dependent pulse number correction for the range from approx. 0,5...7 mm/min. In our laboratory each instrument is calibrated within the intensity range of 0...7 mm/min with a water quantity of 200cm³ (=10 mm precipitation height).
Precipitation transmitters with built-in heating (5.4033.35.xxx) liquefy snow or hail and consequently, are suitable for winter use. All parts are corrosion-resistant. The casing consists of stainless steel (V2A).


Order-No.
Technical Data
5.4033.35.xxx
Heating 70 W; 24 V AC/DC
36.xxx
no
.040
Output/Analogue 0 ... 20 mA (<500 ohm)
.041
4 ... 20 mA (<500 ohm)
.073
0 ... 5 V
.061
0 ... 10 V
  Collecting surface 200 cm²
Resolution 0,1 mm
Measuring range max. 7 mm/min.
Measuring principle tipping bucket
Supply voltage 24 V AC/DC or
(w/o heating)
10 ... 28 V DC
14 ... 28 V DC (10V-output)
Ambient temperature -25... +60°C with heating
0... +60°C w/o heating
Mounting on stand pipe (1 ½")
Weight 3,3 kg