About Thies ClimaNiederschlagPrecipitation Transmitter



 

General InformationPrecipitation Transmitter

This instrument is designed to measure precipitation striking the surface of the earth. The precipitation strikes a collector with a surface area of 200 cm² and then travels via a run-in sieve into a tipping scale. When a certain amount of water has gathered, the scale tips and empties, while the other half of the scale is ready to receive water again. This tipping procedure is detected by a reed switch and is made available as a pulse for an electrical Signal.

The signal is prepared and emitted on the digital output (optocoupler) as a pulse. Simultaneously the input signal is converted in an analog value change and made available on the analog output as a current or voltage value. (See Models Available) The amount of the analog value change depends on the measuring range selected. There are different measuring ranges available (see Selection of Measuring Range). Selection is made by means of a DIP switch and thus can be adjusted by the user to the local conditions. The analog output is set automatically to the initial value (for example 0V..., 4mA..., 0mA...) when the measuring range transmission value has been reached.

Diagramm

Resetting the analog output to the initial value can also be done with a RESET-impulse on the reset-input (at any time). The Precipitation Transmitter is equipped with an electronically regulated heater for winter operation.

Models Available
 
Order - No
Power supply
Output/analog
Measuring range
5.4033.30.040   0 ... 20 mA (max. 500 O )
0 ... 10 mm
5.4033.30.041
24 V
4 ... 20 mA (max. 500 O )
0 ... 20 mm
5.4033.30.061
AC/DC
0 ... 10V
0 ... 25 mm
5.4033.31.040
10 ... 18 V DC
0 ... 20 mA (max. 500/300 W)
0 ... 50 mm
5.4033.31.041   4 ... 20 mA (max. 500/300 W
with DIP - Switch
5.4033.31.061
14 ... 18 V DC
0 ... 10 V
adjustable

The factory setting for the measuring range is 0 ... 10 mm.
 

Technical Data
 
Order No.
5.4033.30.xxx
5.4033.31.xxx
Heating
yes
no
Switch-on temperature 
ca. 5°C
--------
Hysterese
ca. 2°C
--------
Heating power
70W (24V)
--------
Ambient temperature
-25°C ... + 50°C
0 ... + 60°C
Measuring system Tipping bucket
Resolution 0.1 mm
max. Intensity  7 mm/Minutes
analog Measuring range adjustable ( DIP Switch)
Measuring range 1 0 ... 10 mm Precipitation 
Measuring range 2 0 ... 25 mm Precipitation 
Resolution 0.1 mm
Measuring range 3 0 ... 20 mm Precipitation 
Measuring range 4 0 ... 50 mm Precipitation 
Resolution 0.2 mm
analog registration with automatic overflow
with external reset
Reset input Optocoupler
Input voltage 5 ... 30 V
Pulse ³ 20 msec 
Measured value output
1. Digital
Optocoupler 1 Pulse/Tipping bucket
Pulse length >= 100 msec
U (max.) 30 V
2. Analog
Voltage output 0 ... 10 V (corresponds to...s. Measuring range)
Current output 0 ... 20 mA (corresponds to s. Measuring range)
4 ... 20 mA
Non linearity ± 0,2 % (-30°C ... 60°C)
Offset error < 0,3 % (-30°C ... 60°C)
load 500 W Power supply 24 V AC/DC
300 W Power supply 10 ... 14 V DC
Power supply 1. 24 V AC/DC (±15%)
2. 10 ... 18 V DC
Power consumption approx. 20 mA (without heating)