Thies Clima
Radiation 
Radiation
Sunshine Global Radiation Net Radiation UV Radiation Photo Synthesis Heat Flux


Brightness

 

Brightness Transmitter

The instrument serves for the acquisition of the daylight intensity, and is adapted to the sensitivity of the human eye. The linearized electrical output signal can be used for the control of shading devices, heating systems, and irrigation plants.

Brightness Transmitter
Order Code
Technical Data
7.1414.10.xxx
Measuring range 0 - 100 000 lux
7.1414.12.xxx
0 -   20 000 lux
7.1414.15.xxx
0 -     5 000 lux
7.1414.22.xxx
0 -     2 000 lux
          .xx.040
Electrical output 0 - 20 mA (600 Ohm)
          .xx.041
4 - 20 mA (600 Ohm)
          .xx.061
0 - 10 V    (max. 10 mA)
Accuracy ±3 % of mr.
Spectral range 0,350 - 0,775 µm
Half angle ±55 degree
Operating voltage 24 V AC/DC
Protection IP 65
Dimensions 80 x 82 x 65 mm
Weight 0,15 kg

Brightness Transmitter

Measuring sensor for the acquisition of the brightness. It can be used for the regulation of shading devices, heatingand irrigation plants in automatically controlled green houses or as twilight sensor.
There are two analogue outputs available: output 1 offers different, selectable measuring ranges. Output 2 is used as fixed measuring range, particularly for the twilight range. The output signals can be delivered as voltage or current.

Brigtness Transmitter
Bestell - Nr. Technische Daten
7.1414.51.150 Measuring range Output1 programmable 0 - 150 000 Lux
0 - 100 000 Lux
0 - 50 000 Lux
0 - 10 000 Lux
Measuring range Output 2 0 - 1 000 Lux
7.1414.51.550 Measuring range Output1 programmable 0 - 750 Lux
0 - 500 Lux
0 - 250 Lux
0 - 50 Lux
Measuring range Output 2 0 - 5 Lux
Electr. output programmable 0 - 20 mA    (350 Ohm)
4 - 20 mA    (350 Ohm)
0 - 10V       (max. 5 mA)
Spectral range 350 - 820 nm
Accuracy ±3 % of m.r.
Acquisition angle elevation 0 - 90°
azimuth 0 - 360°
operating voltage 15 - 36 V DC ± 10%
15 -24 V AC +15% / -10%
Temp. range - 30 - + 70°C
Protection IP 65
Cable 7.1414.51.150; 5 m
7.1414.51.550; 12 m
Dimensions Ø 70 x 73 mm
Weight 150g (w/o cable)


Brightness Transmitter

Measuring instrument for the acquisition of the daylight intensity.
The electrical output can be used for the regulation of shading devices, heatingand irrigation plants.
The acquisition is carried out in the upper part (dome) of the instrument. The acquisition angle is ± 90 degrees.
The model with “heating” avoids a possible dewing on the dome
.

Order Code Technical Data
7.1414.40.002 Without heating
.102 With heating
Measuring range 0 - 100 000 lux
Electr. Output 0 - 10 V DC
Spectral range 0,350 - 0,820 µm
Acquisition angle Elevation 0.....90°
Azimut 0...360°
Accuracy ±2 % reference unit
Operating voltage electronics 15 ... 28 V DC, 5 mA
heating 24 V AC/DC (±20 %) < 300 mA
Protection IP 65
Dimensions 80 x 82 x 112 mm (w x d x h)
Weight 0,15 kg

Clima Sensor 2000


 Info Info    Home Home