Radiation |
Sunshine Brightness Global Radiation UV Radiation Photo Synthesis Heat Flux |
Net Radiation
Net Radiation Transmitter
Suitable for measuring radiation balance consists of two identical thermocouple elements. The upper plate measures global radiation, the lower one measures the reflected radiation from the surface. The interior is dried by means of silica gel. The instrument is "first class" according to WMO.
Delivery includes calibration certificate.
| Order Code | Technical Data | |
|---|---|---|
|
7.1415.10.000
|
Measuring range | 0 - 1500 W/m² |
| Sensitivity | ca. 15 µV/ W/m² | |
| Spectral range | 0,3 - >30 µm | |
| Impedance | approx. 5 Ohm | |
| Response time | 25s at 95% | |
| Linearity | ±2 % (0,5 - 1330 W/m²) | |
| Dome | Lupolene | |
| Sensor type | Thermocouples | |
| Ambient temp. | - 40 - + 60°C | |
| Cable | 10 m long | |
| Dimensions | 127 x 50 x 35 mm | |
| Weight | 0,35 kg | |
Pyrradiometer
For measurement of the total radiation balance, global radiation and reflected radiation. The measuring values of the global and the reflected radiation are output separately. The instrument is "first class" according to WMO.
Delivery includes calibration certificate.
| Order Code | Technical Data | |
|---|---|---|
|
7.1415.20.000
|
Measuring range | 0 - 1500 W/m² |
| Sensitivity | approx. 15 µV/ W/m² | |
| Spectral range | 0,3 - > 30 µm | |
| Impedance | approx. 190 Ohm / Sensor | |
| Linearity | < 2 % (0,5 - 1330 W/m²) | |
| Response time | 25 s at 95% 45 s at 99% |
|
| Sensor type | Thermocouples | |
| Ambient temp. | - 40 - + 60°C | |
| Cable | 5 m long | |
| Dimensions | Ø 90 x 88 mm | |
| Weight | 1,25 kg | |
Albedometer CM 7B
To measure the short-wave radiation balance, global radiation and reflection radiation. Albedo could be calculated from this measured values. The instrument consists of two identical Pyrradiometers. The upper measures the global radiation, the lower the reflection radiation of the ground. The Pyrradiometers have separate outputs. The interior is dried by means of silica gel.
Delivery includes calibration certificate.
| Order Code | Technical Data | |
|---|---|---|
|
7.1415.25.000
|
Measuring range | 0 - 2000 W/m² |
| Sensitivity | 9 - 15 µV/ W/m² | |
| Spectral range | 0,3 - 2,8 µm | |
| Impedance | 70 - 100 Ohm | |
| Non-linearity | ±1,5 % (< 1000 W/m²) | |
| Response time | 1/e 4 s ; 55 s at 99 % | |
| Sensor type | Thermocouples | |
| Cable | 10 m long | |
| Dimensions | Ø 150 x 115 mm | |
| Weight | 1,9 kg | |
The instrument serves to measure the net radiation. The output signal is in proportion to the net radiation and can be interpreted as radiation energy, which is absorbed from the earth's surface.
| Order Code | Technical Data | |
|---|---|---|
|
7.1415.40.000
|
Measuring range | -200 - +1500 W/m² |
| Sensitivity | 10 µV/ W/ m² | |
| Spectral range | 0,2 - 100 µm | |
| Response time | 20 s | |
| Sensor type | Thermocouples | |
| Ambient temp. | -30 - +70°C | |
| Cable | 3 m long | |
| Dimensions | Ø 80 mm | |
| Support Arm | Ø 16 x 400 mm | |
| Weight | 0,26 kg | |