MISCELLANEOUS DEVICES

Datalogger DLU

  • Description
  • Specification
  • Versions
  • Accessories
  • Further information
  • PDF
Part number: 9.1711.00.000
In addition, one or several measuring value transmitters with RS485 output can be connected to the serial interface COM2. The RS232 interface COM1 or the USB interface can be used for commands and data output. Output of the data is also possible using a memory card (SD card).
The data logger is operated with a 12V rechargeable battery and therefore runs without an external power supply. A rechargeable battery is not included in the scope of supply.
There is also the option to operate the logger with 24V AC/DC by means of a power supply unit, which, at the same time, may serve for charging the storage-battery.
5.1756.00.000

Specification


Part number: 9.1711.00.000
 
5.1756.00.000
Analogue data sampling
A/D - converter
16 bit
Accuracy
±0.1 % of meas. range
Noice ratio
yes @ 50Hz
Precipitation
Electrical input
2 x impulses (0 ... 5 V)
Resolution
0.1 mm
Temperature
Electrical input
1 x PT100
Measuring range
-40 ... +70 °C
Accuracy
±0,1 mK
Rel. Humidity
Electrical input
1 x 0.02 ... 1 V
Measuring range
2 ... 100 % rel. h.
Accuracy
± 0.001 % rel. h.
Serial interfaces
Quantity
2
Configuration
COM1: RS232 or USB
COM2: RS485 HD
Supported devices
COM2:
LPM, US2D, US2D Compact, Clima Sensor US, WSC11
Function
COM1: Configuration, data access
COM2: Sensors, instantaneous values
Data output digital
Interface
COM1: RS232
COM2: RS485 half duplex
Data input digital
Typ
2 x impulses for precipitation
Data management
Measurement cycle
1 ... 3600 s
Memory cycle
1 ... 10 min
Memory capacity
4 MByte
Number data records
303104 ( 4 channels )
147456 ( 10 channels )
Output of archive values
serial via COM1 (ASCII - formatted)
Export to SD - card (ASCII - formatted)
Operating voltage
Electronic
18 ... 36 V DC or
28.5 ... 27.6 V AC
Current consumption
min. 0.1 mA
max. 2.0 mA
Battery connection
for 12 V battery
Internal battery charger
15 ... 18 V / max. 20 W
General
Ambient temp.
-30 ... +60 °C
Electr. connection
clamp
Dosplay
LCD-Display 2 x 16 digits
Mounting
DIN mounting
Protection
IP 20
Dimension
155 x 85 x 60 mm
Weight
0.7 kg

Versions

No other versions of this product are available.

Accessories

 
Product
Product name
Product name / Brief description
9.1700.98.x0x

Meteo-Online

9.1700.98.x01

Meteo-Online


Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/or as text The user has the possibility to place the display-elements free on the screen, and to save them.
 
Data display
Monitor - display
- Values
- Diagrams
- Tables
- Windrose
- Time
- Date
Compatibility
Connectable instruments
- US-Anemometer
- Datalogger
- Clima Sensor
- Weather station WSC11
- Wind display
- etc.
System requirements
PC mit
- Prozessor > 1 GHz
- RAM > 1 GB
Operating system
- Windows 2003 SP2
- Windows Server 2008
- Windows 7
- Windows Server 2008 R2
- Windows 7 SP1
- Windows Server 2008 R2 SP1
- Windows 8
- Windows 10

9.1796.xx.xxx

Mevis Light

9.1796.40.xxx

Mevis Light


PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
 
Compatibility
Connectable instruments
all THIES data logger
System requirements
PC mit
- Prozessor > 1 GHz
- RAM > 1 GB
Operating system
- Windows 2003 SP2
- Windows Server 2008
- Windows 7
- Windows Server 2008 R2
- Windows 7 SP1
- Windows Server 2008 R2 SP1
- Windows 8
- Windows 10

Software
max. stations
5
max. components per station
30
ASCII - import
not available
MEVIS data path
fix, not changeble
automatical data export
only manually via dialog
Extentions
no
Lizence protection
intalledUser
9.1796.xx.xxx

Mevis Full Version

9.1796.50.xxx

Mevis Full Version


PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
 
Compatibility
Connectable instruments
all THIES data logger
System requirements
PC mit
- Prozessor > 1 GHz
- RAM > 1 GB
Operating system
- Windows 2003 SP2
- Windows Server 2008
- Windows 7
- Windows Server 2008 R2
- Windows 7 SP1
- Windows Server 2008 R2 SP1
- Windows 8
- Windows 10

Software
max. stations
99
max. components per station
99
ASCII - import
available
MEVIS data path
configurable
automatical data export
available
Extentions
MEVIS viewer
Lizence protection
hardware dongle
9.2200.00.000

SD-Card

9.2200.00.000

SD-Card


Serves as portable data carrier for reading the measuring data out from data logger
 
Data management
Memory capacity
2 GByte
Format
FAT 16
9.3293.00.000

Protection housing

9.3293.00.000

Protection housing


Protection housing with clear cover
 
General
Power supply
85 ... 264 V AC 45 ...65 HZ/ 24 V DC 60 W
Mounting
wall mounting
Dimension
252 x 162 x 120 mm
Fixing boring
DIN rail 35 x 7.5 mm 240 mm long
Matirial housing
plastic

Further information

 
 
 
Catalogs
Catalog WindCatalog PrecipitationCatalog RadiationCatalog Temperature, Pressure, Humidity
 

Contact
Phone: +49 551 / 79001-0
Fax: +49 551 / 79001-65
info@thiesclima.com

Inquiry / Message

Please use the form below for your inquiry or message.
 
 
Datalogger DLU (9.1711.00.000)

Member of

Exhibitions 2017

Meteorological Technology World Expo
Booth 10065
October 10– 12, 2017, Amsterdam, Netherlands

Product news

Ultraschall Anemometer WP
Serves for the 2-dimensional acquisition of the horizontal components...

Ceramic rain monitor

The rain monitor is designed to act as a sensor detecting the start and end of precipitation...
Datenlogger Universal DLU
The datalogger DLU is a complete measuring system...
THE WORLD OF WEATHER DATA