Wind speed | |
Measuring range | 0 ... 75 m/s |
Resolution | 0.1 m/s (standard) 0.01 m/s (user defined) |
Accuracy | ±0.2 m/s rms ( < 5 m/s ) ±2 % rms ( 5 ... 50 m/s ) |
Wind direction | |
Measuring range | 0 ... 360 ° |
Resolution | 1 ° 1 ° (standard) < 1 ° (user defined) |
Accuracy | ±2 ° @ 2 m/s < WS < 50 m/s |
Virtual temp. | |
Measuring range | -40 ... +70 °C |
Resolution | 0.1 K |
Data output digital | |
Interface | RS485 / RS422 |
Baudrate | 1200 ... 921600 Baud |
Data values | instant. values, average values |
Output range | 1 per 100 msec up to 1 per 50 sec |
Status signals | heating, Meas section error, Temperature of meas section |
Protocol | ASCII, MODBUS RTU, NMEA WV |
Data output analog | |
Wind speed | 0 ... 20 mA 4 ... 20 mA 0 ... 10 V 2 ... 10 V |
Stromausgang | max. 500 Ω |
Wind direction | 0 ... 20 mA 4 ... 20 mA 0 ... 10 V 2 ... 10 V |
Voltage output | min. 50 kΩ |
Resolution | 16 bit |
Operating voltage | |
Electronic | 8 ... 40V DC or 12 ... 28 V AC / 2.5 W |
Heating | 24 V AC/DC, typ 100 W |
Heating | |
Heated compontents | base plate, cover plate, connecting pipes, ultrasonic transducers |
General | |
Bus operation | up to 98 sensors |
Electr. connection | 8 pol. connector |
Housing | seawater-proof, stainless steel (V4A) and aluminium |
Protection | IP 67 |
Dimension | Ø 100 mm x 120 mm |
General | |
Mounting | on a mast tube 1 " |
Weight | 0.9 kg |
General | |
Mounting | on a mast tube 1,5 " |
Weight | 1.1 kg |
Data output digital | |
Protocol | MODBUS |
General | |
Mounting | on a mast tube 1 " |
Weight | 0.9 kg |
Data output digital | |
Protocol | MODBUS |
General | |
Mounting | on a mast tube 1,5 " |
Weight | 1.1 kg |