Clima Sensor US
Part number: 4.920x.x0.00x
-
Description
CLIMA Sensor US - Compact precision for demanding weather applications
The CLIMA Sensor US combines state-of-the-art sensor technology, such as ultrasonic wind measurement and radar technology for precipitation measurement, in a compact, maintenance-free design. Whether for building automation, solar parks, smart cities, agriculture or meteorology - the sensor reliably delivers precise measurements of all relevant weather parameters.
Thanks to various versions, the sensor offers customized parameter combinations for a wide range of applications. An integrated GPS receiver and an electronic compass enable exact time synchronization as well as position and location-dependent calculations in combination with the measured weather data.
The CLIMA Sensor US offers a comprehensive range of weather data - combined with state-of-the-art measurement accuracy and maintenance-free technology. Integration into existing infrastructures is facilitated by various communication interfaces (Modbus, ASCII, 0-10V), while the shockproof and UV-resistant LEXAN® housing reliably protects the sensor even in extreme environments (-50°C to +80°C).
Recorded weather parameters:
Wind: Wind speed, wind direction (ultrasonic technology)
Radiation & light: Global radiation, brightness (4 hemispheres), twilight
Precipitation: status, amount, intensity, type
Air values: temperature, absolute & relative humidity, dew point
Air pressure: Absolute & relative air pressure
GPS receiver: Position, altitude, time, date, sun position,
E-compass: North orientation
Typical areas of application:
Solar parks & PV performance measurement: Optimization of energy yields
Building automation: intelligent control of air conditioning, shading and ventilation systems
Smart city: environmental monitoring and weather forecast models
Agriculture & greenhouses: Precise control of irrigation and climate
Meteorology & research: High-precision recording of weather and climate dataSpecification
Wind speedMeasuring range0 ... 60 m/sResolution0.1 m/s ( standard )Accuracy0 ... 10 m/s ± 0.25 m/s (rms - mean over 360 °)
10 ... 30 m/s ± 2.5 % (rms - mean over 360 °)
30 ... 60 m/s ± 3.5 % (rms - mean over 360 °)Wind directionMeasuring range0 ... 360 °Resolution1 °
0.1 ° in special telegramsAccuracy±2 ° WS > 2 m/sData output digitalInterfaceRS485 / RS422Baudrate1200 ... 921600 BaudData valuesdiv. meas. data, date, time, check sum, Precipitation type according to Synop etc.Output range1 per 10 msec up to
1 per 60secStatus signalsheating, Meas section error, Temperature of meas sectionProtocolASCII ( preselected )Data output analogTypemax. 8 x 0 ... 10 VWind speed0 ... 10 VStromausgangmax. 400 ΩWind direction0 ... 10 VVoltage outputmin. 2000 ΩOutput parameterswind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure, etc,Operating voltageElectronic6 ... 40V DC or
10 ... 28 V AC / typ. 50mA @ 24VHeating24 V AC/DC, typ 1,4 A @ 24VGeneralBus operationup to 98 sensorsElectr. connection19 pol. connectorMountingon a mast tube 1,5``HousingPlastic LEXAN (Polycarbonat, UV-stabilised)ProtectionIP 67Versions
Product number 4.9201.00.001TemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 % ... 90 % rel. H. )Air pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgProduct number 4.9202.00.000PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionBrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueData output analogOutput parameterswind speed, wind direction, brightness, precipitation, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9202.00.001PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy±30 W/m² im Vergleich zu einem Class B Pyranometer, berechnet aus Helligkeiten und SonnenstandBrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueData output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, brightness, precipitation, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9203.00.000Data output analogOutput parameterswind speed, wind direction, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9200.00.000PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionTemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 % ... 90 % rel. H. )BrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueAir pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output analogOutput parameterswind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgProduct number 4.9200.00.001PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionTemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 ... 90 % rel. H. )BrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueAir pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgProduct number 4.9203.00.001Data output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9200.20.001PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionTemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rain TemperatureMeasuring range5 … 50 °CAccuracy0,5 °CRel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 ... 90 % rel. H. )BrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of measuring valueAir pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgProduct number 4.9201.00.000TemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 % ... 90 % rel. H. )Air pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output analogOutput parameterswind speed, wind direction, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgProduct number 4.9202.20.000PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionRain TemperatureMeasuring range5 … 50 °CAccuracy0,5 °CBrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueData output analogOutput parameterswind speed, wind direction, brightness, precipitation, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9202.20.001PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionRain TemperatureMeasuring range5 … 50 °CAccuracy0,5 °CBrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. Measuring valueData output digitalProtocolMODBUS RTU ( preselected )Data output analogOutput parameterswind speed, wind direction, brightness, precipitation, etc.GeneralDimensionØ 150 x 175 mmWeight0.7 kgProduct number 4.9200.20.000PrecipitationMeasuring range general0.001 ... 10 mm/minAccuracytyp. 95%RadiationMeasuring range0 ... 2000 W/m²Accuracy± 30 W/m² compared to a Class B pyranometer, calculated from brightness and sun positionTemperatureMeasuring range-50 ... +80 °CAccuracy±0,3 K ( @ 25 °C )Rain TemperatureMeasuring range5 … 50 °CAccuracy0,5 °CRel. HumidityMeasuring range0 ... 100 % rel. h.Accuracy± 1.8 % rel. h. ( 10 ... 90 % rel. H. )BrightnessMeasuring range0 ... 150 kLuxAccuracy3 % of rel. measuring valueTwilightMeasuring range0 ... 250 LuxAccuracy3 % of rel. measuring valueAir pressureMeasuring range260 ... 1260 hPaAccuracy±0.25 hPa @ - 20 ... +80 °C @ 800 ... 1100 hPa
±0.50 hPa @ - 20 ... +80 °C @ 600 ... 800 hPa
±1.00 hPa @ - 50 ... -20 °C @ 600 ... 1100 hPaData output analogOutput parameterswind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc.GeneralDimensionØ 150 x 220 mmWeight0.9 kgAccessories
ProductProduct nameProduct name / Brief description509311Cable for Clima Sensor US
Cable for Clima Sensor US
Cable assembled, 16-core connecting cable for Clima Sensor US
• length 10 m509427Cable for Clima Sensor US
Cable for Clima Sensor US
Cable assembled, 8-core connecting cable for Clima Sensor US.
• length 10 m9.1700.81.000Thies Device Utility
Thies Device Utility
The PC program “Thies Device Utility” serves for the initial operation and configuration of Thies sensors with serial interface.
The program can find all sensors connected to the PC, and facilitates an initial operation via terminal function. Thanks to a user-friendly surface design the communication with the sensors is very easy.9.3389.20.000Power supply Unit
Power supply Unit
Serves for the power supply of the ClimaSensor US as well as for the connection and distribution of cable resp. cable wires.
primary:
• 230 V AC
secundary:
• 24 V AC / 30 WFurther information