Close window

Ultrasonic Anemometer 2D

Part number: 4.3820.34.398

  • Description

    4.3820.xx.xxx
    The Ultrasonic Anemometer 2D serves for the 2-dimensional acquisition of the horizontal components of the wind velocity, the wind direction as well as of the acoustic-virtual temperature.
    The model no. 4.3820.34.398 is equipped with an additional case heating (supply:
    24 V AC/­DC, 240 W ) for the use at extremely critical sites, where frequent icing might be expected
    More than 35 different measurement values are available, for ex.:
    • Orthogonal wind velocity
    vectors (X- and Y-distance)
    • Scalar wind velocity
    • Wind direction
    • Acoustic-virtual temperature
    • Acoustic-virtual temperature of the orthogonal measurement distances (X- and Y-distance)
    • Standard deviation of the vectorial wind velocity
    (X and Y-distance)
    • Standard deviation of the scalar wind velocity
    • Standard deviation
    of the wind direction
    • Standard deviation of the acoustic-virtual temperature
    • Wind velocity of the gust acc. to WMO
    • Wind direction of the gust acc. to WMO

    The instrument is especially suitable for the use in the fields of
    • Meteorology
    • Climatology
    • Regenerative energy, wind energy plant
    • Traffic engineering, aviation and navigation
    • Pollutant dispersal
    • Wind alarm devices, building construction and building safety
    • Indoor flow measurement
    • And in alpine field of application

    The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.
    The measurement values can be transmitted digitally and/­or in analogue form.
    The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.
    If necessary, the sensor arms are automatically heated in case of critical ambient emperatures. The possibility of malfunction, caused by icing, is minimized.
    Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suitable even for the more difficult use in locations where frequently icing is to be expected
  • Specification

    Data output digital
    Interface
    RS485 /­ RS422
    Baudrate
    1200 ... 921600 Baud
    Data values
    instant. values, average values, standard deviation
    Output range
    1 per 10 msec up to
    1 per 60sec
    Status signals
    heating, Meas section error, Temperature of meas section
    Data output analog
    Wind speed
    0 ... 20 mA
    4 ... 20 mA
    0 ... 10 V
    2 ... 10 V
    Stromausgang
    max. 400 ê
    Wind direction
    0 ... 20 mA
    4 ... 20 mA
    0 ... 10 V
    2 ... 10 V
    Voltage output
    min. 4000 ê
    Resolution
    16 bit
    Data input analog (alternative)
    Chanels
    3
    Resolution
    16bit
    Operating voltage
    Electronic
    8 ... 60V DC or
    12 ... 42 V AC /­ 2.5 W
    Heating
    24 V AC/­DC, typ 240 W
    General
    Bus operation
    up to 98 sensors
    Electr. connection
    8 pol. connector
    Mounting
    on a mast tube 1,5``
    Housing
    stainless steel (V4A) AiSi316Ti
    Protection
    IP 65
    Dimension
    Ø 424 mm x 287 mm
    Weight
    2.5 kg
  • Versions

     
    4.3820.xx.xxx
    Product number 4.3820.00.300
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Full duplex
    Data telegram
    no independent telegram output
    Product number 4.3820.00.340
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Full duplex
    Data telegram
    VDT-Telegram (Telegram2)
    Output range
    10 per 1 sec
  • Accessories

    Product
    Product name
    Product name / Brief description
    4.3800.90.000

    Ultrasonic Bird delfector

    4.3800.90.000

    Ultrasonic Bird delfector


    The Ultrasonic Bird Deflector protects the ultrasonic anemometer against measurement faults, which might be caused by different species of birds.
     
    Data output digital
    Switching output
    max. 24 V AC/­DC
    Interface
    Type
    RS485
    Data format
    8N1
    Baud rate
    2400 ... 115200 Baud
    General
    Power supply
    12 ... 24V DC
    24 V AC
    Electr. connection
    cable gland
    Housing
    Polycarbonate
    Protection
    IP 65
    Weight
    0.2 kg
    507245

    Device to refuse birds

    507245

    Device to refuse birds


    The device to refuse birds shall prevent smaller birds in the distance of the US transformer from sitting on the instrument, thus providing for an undisturbed operation.
     

    Connecting cable 20 m

    507752

    Connecting cable 20 m


    Model with

    • length 20 m
     
    General
    Cable length
    20 m

    Connecting cable 25 m

    507753

    Connecting cable 25 m


    Model with

    • length 25 m
     
    General
    Cable length
    25 m

    Connecting cable

    50775x

    Connecting cable


    Suitable cable for 4.3820/­30/­75/­80/­81

    • length: see versions
     
    General
    Cable length
    see versions
    Cable
    PUR 4 x 0,75 +2x2x0,14 mm²
    508396

    Bird spike

    508396

    Bird spike


    The bird spike prevents bigger birds from resting in the measurement path between the ultrasonic transducers, providing an undisturbed operation.
     
    General
    Material
    V4A (AiSi 316L)
    9.1700.98.x0x

    Meteo-Online

    9.1700.98.x01

    Meteo-Online


    Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/­or as text The user has the possibility to place the display-elements free on the screen, and to save them.
     
    Data display
    Monitor - display
    - Values
    - Diagrams
    - Tables
    - Windrose
    - Time
    - Date
    Compatibility
    Connectable instruments
    - US-Anemometer
    - Datalogger
    - Clima Sensor
    - Weather station WSC11
    - Wind display
    - etc.
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
  • Further information