Close window

Data logger DL16

Part number: 9.172x.xx.xxx

  • Description

    9.1721.00.000
    The DL16 meets all requirements for meteorological applications. Its flexibility allows the measuring value acquisition of common sensors as well as the connection of instruments from other manufacturers via RS485, RS422, Ethernet, and also via the analogue inputs.
    The Datalogger DL16 is a complete measuring system for automatic acquisition and storing of meteorological and environmental measuring data: wind velocity, wind direction, temperature, precipitation, rel. air humidity, radiation, etc. In doing so, the DL 16 is characterized by its high flexibility.
    Due to its internal structure it is possible to interlink any measuring values, to average individually, and to store in different intervals. For this, 4Mbyte data are available for the configuration, and 8Mbyte as data storage. For memoryintensive application also the storage of the SD card with a capacity of up to 4Gbyte can be used as archive. There are sampling intervals of 1 sec ... 10 min available, in which wind velocity values can be sampled by up to 4 Hz.
    The acquisition and processing of all signals is conform to WMO recommendations and IEC 61400-12-1.
  • Specification

    Analogue data sampling
    A/­D - converter
    24 bit
    Accuracy
    ±0.01 % of meas. range
    Noice ratio
    typ. 100dB @ 50Hz
    Input voltage
    fully bipolar inputs with typ. 20 V common-mode input voltage range
    Multifunction inputs
    Quantity
    16
    Function
    6 x wind speed
    8 x wind direction
    6 x counter
    16 x PT100
    16 x PT1000
    16 x -40 ... 40 mV
    16 x 0 ... 100 mV
    16 x 0 ... 1 V
    16 x 0 ... 10 V
    16 x 0 ... 20 mA
    16 x 4 ... 20 mA
    16 x status ( 0 ... 5 V)
    Precipitation
    Electrical input
    6 x impulses (0 ... 5 V)
    16 x status ( 0 ... 5 V)
    Wire break detection
    yes
    Resolution
    0.1 or 0.2 mm
    Radiation
    Electrical input
    16 x -40 ... 40 mV
    Accuracy
    ±1 W/­m² ( @ 15 µV/­W sensitivity )
    Temperature
    Electrical input
    16 x PT100
    16 x PT1000
    Measuring range
    -40 ... +70 °C
    Accuracy
    ±0,01 mK
    Rel. Humidity
    Electrical input
    16 x 0 ... 1 V
    wire break detection
    yes
    Measuring range
    0 ... 100 % rel. h.
    Accuracy
    ±0.0001% rel. h.
    Air pressure
    Electrical input
    16 x 0 ... 5 V
    Measuring range
    800 ... 1060 hPa
    Accuracy
    ±0.0005 hPa
    Miscellaneous
    Electrical input
    16 x 0 ... 100 mV
    16 x 0 ... 1 V
    16 x 0 ... 10 V
    16 x 0 ... 20 mA
    16 x 4 ... 20 mA
    1 x high current input 0 ... 1 A (galvanic decoupled)
    1 x high current 0 ... 10 A (galvanic decoupled)
    Serial interfaces
    Quantity
    7
    Configuration
    COM1: USB
    COM2: RS232 or RS485 HD/­FD
    COM3: RS232 or RS485 HD/­FD
    COM4: RS485 HD/­FD
    COM5: RS485 HD/­FD
    COM6: optional with aditional interface
    Ethernet: UDP, WEB, FTP
    Supported devices
    COM2, COM3, COM4, COM5, COM6 supports:
    LPM, US2D, US2D Compact, Clima Sensor US, WSC11, Sensor Interface
    Function
    COM1: Configuration
    COM2: Sensors, data access
    COM3: Sensors, data access
    COM4: Sensors, data access
    COM5: Sensors, data access
    COM6: Sensors, data access, modem
    Ethernet: Configuration, Sensors, data output, NTP
    Data output digital
    Output type
    4 x heavy-power disconnectors max. 60V DC/­AC and max 10 A each
    Data management
    Measurement cycle
    1 ... 3600 s
    Memory cycle
    1 ... 3600 s
    Memory capacity
    8 MByte internal
    1 x SD card via slot
    Number data records
    storing cpacity max. 1 year, depending to configuration
    Output of archive values
    serial via COM1 (ASCII - formatted)
    serial via COM2 (ASCII - formatted)
    serial via COM3 (ASCII - formatted)
    serial via COM4 (ASCII - formatted)
    serial via COM5 (ASCII - formatted)
    serial via Telnet (ASCII - formatted)
    Export to SD - card (ASCII - formatted)
    Time base
    Type
    real-time clock with automatic leap-year identification, battery-backed
    Synchronisation
    ±3.5 ppm = ± 0.3 s /­ 24 h in the range from -40…+85°C; NTP, DCF77, GPS - receiver
    Operating voltage
    Electronic
    110 ... 230 V AC
    Current consumption
    min. 3.5 mA
    max. 115.0 mA
    Battery connection
    for 12 V battery
    Internal battery charger
    15 ... 18 V
    General
    Operation
    1 rotary switch on device. Remote operation via serial interfaces (COM1, USB) or Ethernet (Telnet)
    Ambient temp.
    -30 ... +60 °C
    Electr. connection
    clamp
    Dosplay
    LCD-Display 4 x 20 digits
    Mounting
    mast tube or wall
  • Versions

     
    9.1721.00.000
    Product number 9.1720.00.000
    General
    Protection
    IP 66
    Dimension
    300 x 380 x 155mm
    Weight
    6 kg
    Product number 9.1721.00.000
    General
    Protection
    IP 66
    Dimension
    380 x 600 x 210 mm
    Weight
    8 kg
  • Accessories

    Product
    Product name
    Product name / Brief description
    9.1700.98.x0x

    Meteo-Online

    9.1700.98.x01

    Meteo-Online


    Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/­or as text The user has the possibility to place the display-elements free on the screen, and to save them.
     
    Data display
    Monitor - display
    - Values
    - Diagrams
    - Tables
    - Windrose
    - Time
    - Date
    Compatibility
    Connectable instruments
    - US-Anemometer
    - Datalogger
    - Clima Sensor
    - Weather station WSC11
    - Wind display
    - etc.
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    9.1796.xx.xxx

    Mevis Light

    9.1796.40.xxx

    Mevis Light


    PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
     
    Compatibility
    Connectable instruments
    all THIES data logger
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    Software
    max. stations
    5
    max. components per station
    30
    ASCII - import
    not available
    MEVIS data path
    fix, not changeble
    automatical data export
    only manually via dialog
    Extentions
    no
    Lizence protection
    intalledUser
    9.1796.xx.xxx

    Mevis Full Version

    9.1796.50.xxx

    Mevis Full Version


    PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
     
    Compatibility
    Connectable instruments
    all THIES data logger
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    Software
    max. stations
    99
    max. components per station
    99
    ASCII - import
    available
    MEVIS data path
    configurable
    automatical data export
    available
    Extentions
    MEVIS viewer
    Lizence protection
    hardware dongle
  • Further information

Privacy settings
This website uses cookies. Some of them are necessary, while others help us to improve this website and your experience.
I agree and can revoke or change my consent at any time with effect for the future.