Close window

Data logger DLX Met

Part number: 9.1756.x0.xxx

  • Description

    9.1756.00.000
    The datalogger DLx-MET is a complete measuring system for the automatic data acquisition
    and storing of meteorological data (for ex. wind velocity, wind direction, temperature,
    precipitation, rel. air humidity, radiation etc.).
    The instrument is to be operated easily via three keys or via the serial interface COM 1 and USB. A three-line alphanumeric display (LCD) serves as indicator. The instrument is supplied by an integrated 12V-battery, and the operation is completely mains independent thanks to the special low power design with respective solar panel and integrated solar controller. An integrated transformer offers the operation at 115 V /­ 230 V power supply.
    Three serial interfaces COM 1- COM 3 and in addition one USB offer – beside the communication – also the connection of sensors with respective operation modes (RS232 or RS285).
  • Specification

    Analogue data sampling
    A/­D - converter
    24 bit
    Accuracy
    ±0.1 % of meas. range
    Precipitation
    Electrical input
    1 x impulses (0 ... 5 V)
    1 x status ( 0 ... 5 V)
    Resolution
    0.1 mm
    Radiation
    Electrical input
    1 x 0 ... 40 mV
    Accuracy
    ±2.7 W/­m² @ 15mW/­m² sensitivity
    Temperature
    Electrical input
    2 x PT100
    Measuring range
    -40 ... +70 °C
    Accuracy
    ±0,1 mK
    Rel. Humidity
    Electrical input
    1 x 0 ... 1 V
    Measuring range
    0 ... 100 % rel. h.
    Accuracy
    ± 0.001% rel. h.
    Air pressure
    Electrical input
    0 ... 5 V
    Measuring range
    configurable 500 ... 1200 hPa
    Accuracy
    ±0.005 hPa
    Miscellaneous
    Electrical input
    0 ... 20 mA
    Measuring range
    0 ... 100 %
    Serial interfaces
    Quantity
    3
    Configuration
    COM1: USB or RS232 or RS485 (Full duplex)
    COM2: RS232 or RS485 (Full duplex)
    COM3: RS485 (Half duplex)
    Supported devices
    COM2 /­ COM3 supports:
    LPM, US2D, US2D Compact, Clima Sensor US, Sensor interface
    Function
    COM1: data access
    COM2: sensor connection or output of instantaneous data
    COM3: sensor connection or output of instantaneous data
    Data input analog
    Meas. range
    skaled to 0 ... 100 %
    Input type
    0 ... 20 mA
    Data input digital
    Typ
    1 x wind speed
    1 x wind direction (synchron serial)
    1 x precipitation counter (0.1 or 0.2 mm)
    1 x precipitation status
    Data management
    Measurement cycle
    1 ... 3600 s
    Memory cycle
    1 ... 60 min
    Memory capacity
    2 MByte
    Number data records
    61570 (10 channels)
    Output of archive values
    serial via COM1 (ASCII - formatted)
    Export to SD - card (ASCII - formatted)
    Channel extension
    Sensor interface SIF001
    6 x Radiation (0 ... 20 mV)
    2 x Temperature (PT100)
    Sensor interface SIF002
    1 x 0 ... 10 V
    2 x 0 ... 1 V
    3 x Radiation (0 ... 20 mV)
    3 x Temperature (PT100)
    Sensor interface SIF003
    2 x 0 ... 10 V
    2 x Radiation (0 ... 40 mV)
    2 x 0 ... 20 mA
    3 x Temperature (PT100)
    Sensor interface SIF004
    2 x 0 ... 10 V
    2 x Radiation (0 ... 40 mV)
    1 x 4 ... 20 mA
    1 x 0 ... 20 mA
    3 x Temperature (PT100)
    Operating voltage
    Electronic
    230 V AC
    Current consumption
    max. 1 mA (measmode, display off)
    max. 12 mA (measmode, display on)
    Battery connection
    internal battery 12 V, 6,5Ah
    Internal battery charger
    15 ... 18 V /­ max. 20 W
    General
    Ambient temp.
    -30 ... +60 °C
    Electr. connection
    clamp
    Dosplay
    LCD-Display 3 x 16 digits
    Housing
    stainless steel
    Protection
    IP 65
    Dimension
    380 x 300 x 155 mm
    Weight
    6.5 kg
  • Versions

    No other versions of this product are available.
  • Accessories

    Product
    Product name
    Product name / Brief description
    9.1700.98.x0x

    Meteo-Online

    9.1700.98.x01

    Meteo-Online


    Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/­or as text The user has the possibility to place the display-elements free on the screen, and to save them.
     
    Data display
    Monitor - display
    - Values
    - Diagrams
    - Tables
    - Windrose
    - Time
    - Date
    Compatibility
    Connectable instruments
    - US-Anemometer
    - Datalogger
    - Clima Sensor
    - Weather station WSC11
    - Wind display
    - etc.
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    9.1796.xx.xxx

    Mevis Light

    9.1796.40.xxx

    Mevis Light


    PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
     
    Compatibility
    Connectable instruments
    all THIES data logger
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    Software
    max. stations
    5
    max. components per station
    30
    ASCII - import
    not available
    MEVIS data path
    fix, not changeble
    automatical data export
    only manually via dialog
    Extentions
    no
    Lizence protection
    intalledUser
    9.1796.xx.xxx

    Mevis Full Version

    9.1796.50.xxx

    Mevis Full Version


    PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
     
    Compatibility
    Connectable instruments
    all THIES data logger
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    Software
    max. stations
    99
    max. components per station
    99
    ASCII - import
    available
    MEVIS data path
    configurable
    automatical data export
    available
    Extentions
    MEVIS viewer
    Lizence protection
    hardware dongle
  • Further information