Close window

Rain Monitor

Part number: 5.4106.0x.xxx

  • Description

    5.4106.00.000
    The instrument is designed for electrical acquisition of start and end of precipitation.
    The precipitation drops are detected by a sensor area, and with wetting a contact is closed.
    An integral heating system ensures ice and snow free operation in winter.
    Complete with a mast fixing that can also be utilised for wall mounting.
  • Specification

    Precipitation
    Collecting area
    18 cm²
    Meas. principle
    ceramic, capacitive sensor
    Switch-on-delay
    < 0.5 s
    Switch-off-delay
    approx. 15 s
    Sensitivity
    appr. 0.2 mm/­h
    Data output digital
    Contact load
    max. 26 VAC /­ 36 VDC
    Switching output
    max. 26 VAC /­ 36 VDC
    General
    Power supply
    11 ... 28 VAC or 11 ... 32 VDC
    ( max 0.75 A )
    Ambient temp.
    -30 ... +60 °C
    Electr. connection
    Item specific
    Mounting
    at mast tube or wall mounting
    Material
    Polycarbonat, Ceramic, stainless steel
    Protection
    IP 66
    Dimension
    77 x 49 x 37,5 mm
    Weight
    0.16 kg
  • Versions

     
    5.4106.00.000
    Product number 5.4106.00.011
    Data output digital
    Electr. output
    semiconductor relais, potential free, electrically isolated,
    normally open contact
    General
    Measuring value
    Precipitation yes /­ no
    Cable
    10m cable, 4 pol., cable shielded, uv-resistant
    Product number 5.4106.00.901
    Data output digital
    Electr. output
    semiconductor relais, potential free, electrically isolated,
    normally open contact
    General
    Measuring value
    Precipitation yes /­ no
    Cable
    3m cable, 4 pol.
    Product number 5.4106.01.011
    Data output digital
    Electr. output
    semiconductor relais, potential free, electrically isolated,
    normally open contact
    General
    Measuring value
    Precipitation detected: (5Hz, 10 - 50Hz)
    Cable
    10m cable, 4 pol., cable shielded, uv-resistant
    Product number 5.4106.00.100
    Data output digital
    Electr. output
    semiconductor relais, potential free, electrically isolated,
    changeover contact
    General
    Measuring value
    Precipitation yes /­ no
    Cable
    3m cable, 5 pol.
  • Accessories

    No accessories are available for this product.
  • Further information