Heat Flux Plate HFP01
Part number: 7.1417.10.000
-
Description
HFP01 measures heat flux through the object in which it is incorporated or on which it is
mounted, in W/m2
The sensor in HFP01 is a thermopile. This thermopile measures the temperature difference across the ceramicsplastic composite body of HFP01. A thermopile is a passive sensor; it does not require power. Using HFP01 is easy. It can be connected directly to commonly used data logging systems. The heat flux in W/m² is calculated by dividing the HFP01 output, a small voltage, by the sensitivity. The sensitivity is provided with HFP01 on its calibration certificate.
A typical measurement location is equipped with 2 or more sensors. HFP01 is the world’s most popular sensor for heat flux measurement in the soil as well as through walls and building envelopes.
Unique features and benefits
• low thermal resistance (essential for use on walls and windows)
• large guard area (required by the ISO 9869 standard)
• low electrical resistance (low pickup of electrical noise)
• high sensitivity (good signal to noise ratio in low-flux environments such as buildings)
• robustness, including a strong cable
• IP protection class: IP67 (essential for outdoor application)Specification
Heat fluxMeasuring range-2000 ... 2000 W/m²Sensitivity60 µV/W/m²Typ. signal output-120 ... +120 mVSensor typeThermocouplesImpedance1 ... 4 êAccuracy±3 %Time response4 minTemperature coefficient0.1 %/KGeneralAmbient temp.-30 ... +70 °CElectr. connection5 m cableProtectionIP 67DimensionØ 80 x 5.4 mmWeight0.2 kgVersions
No other versions of this product are available.Accessories
No accessories are available for this product.Further information
This website uses cookies. Some of them are necessary, while others help us to improve this website and your experience.
I agree and can revoke or change my consent at any time with effect for the future.