Close window

Net Radiometer NR Lite

Part number: 7.1415.40.000

  • Description

    7.1415.40.000
    Instrument measures the differences between global radiation and the reflected radiation from ground.
    Instrument for the measurement of the net radiation, that means the instrument forms the difference between the global radiation from above (solar radiation and long-wave atmospheric counter radiation) and the global radiation from below (short-wave and long-wave
    reflection radiation of the earth)
    The output signal is in proportion to the net radiation, and can be interpreted as radiation
    energy which is absorbed from the earth’s surface.
  • Specification

    Radiation
    Measuring range
    -2000 ... 2000 W/­m²
    Sensitivity
    10 µV/­W/­m²
    Typ. Signal output
    -25 ... 24 mV
    Spectral range
    200 ... 100 000 nm
    Response time
    20 sec
    Sensor type
    thermo-element
    General
    Ambient temp.
    -30 ... +70 °C
    Electr. connection
    cable, 15 m long
    Dimension
    Ø 80
    Weight
    0.26 kg
  • Versions

    No other versions of this product are available.
  • Accessories

    Product
    Product name
    Product name / Brief description
    7.1415.00.200

    Universal Amplifier

    7.1415.00.200

    Universal Amplifier


    The Universal Amplifier serves for the connection of various sensors with voltage-, or PT100 output.
     
    Data output digital
    Interface
    RS485 /­ RS422
    Baudrate
    1200 ... 115200 Baud
    Data output analog
    Chanels
    3
    Output parameters
    0 ... 1 V, 0 ... 5 V,
    0 ... 10 V, 4 ... 20 mA,
    0 ... 20 mA
    Resolution 1/­10000 FS
    Data input analog
    Chanels
    4
    Meas. range
    0.1 ... 1V
    resolution 1 µV
    switchable to -1 ... +10 V

    Alternatively, each
    channel is switchable to PT 100:
    max. -99.0 … +99.0 °C
    PT100 resolution: 1/­10, 1/­100, 1/­1000 °C, settable
    General
    Power supply
    7 ... 24 V DC
    Ambient temp.
    -40 ... +60 °C
    Electr. connection
    Cable gland and terminal strip
    Protection
    IP 65
    Dimension
    120 x 80 x 55 mm
    Weight
    0.25 kg
    Matirial housing
    Polycarbonate

    Preamplifier

    7.1415.01.841

    Preamplifier


    Instrument for transforming small mV-signals from the radiation sensor into a standardized voltage signal.
     
    Data output analog
    Chanels
    1
    Output type
    4 ... 20 mA
    Output range
    0 ... 1600 W/­m²
    Data input analog
    Chanels
    1
    Input type
    -10 ... 75 mV
    General
    Power supply
    7.5 ... 45 V DC ( via 4 ... 20 mA lines )
    Ambient temp.
    -40 ... +85 °C
    Electr. connection
    2 x cable gland
    Protection
    IP 66
    Dimension
    64 x 98 x 34 mm
    Weight
    0.3 kg
    Matirial housing
    aluminium, powder coated
  • Further information