Close window

Mevis Full Version

Part number: 9.1796.50.xxx

  • Description

    9.1796.xx.xxx
    PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
    he acquisition and processing of data from the most different environmental measuring systems require a safe filing, graphical display, further processing of compact data within word processing systems, transmission to other working places and so on. These are standard requirements of a modern software.

    The measuring acquisition-, processing- and information system MEVIS covers the functions for implementing station processors, processors for measuring vehicles and meteorological network centres.

    What is important with this software?

    The Thies dataloggers supply all measured data for transmission, analysis, display and documentation.

    Thies makes use of the software Mevis T-light, especially programmed for meteorological applications.

    The program runs under WindowsTM. The user surface is well-known and easy-to- use. The measured values can also be processed in other programs.
    In short: Mevis under Windows is a special software with common standard applications - thus easy to use.

    The Mevis full-version feature a handling for up to 99 stations, as well as extensive text and graphic report functions, etc.

    Functions

    Connection PC-datalogger

    • Cable (max. 99 stations) via all serial interfaces
    • Modem (max. 99 stations) via all serial interfaces

    Acquisition::

    • max. 99 components (channels per station)
    • mean values (sums)
    • extreme values

    epending on the connected datalogger system MEVIS light can calculate and display the following additional values:

    • Linking (+-x./­.)
    • Rel. humidity
    • Dew point
    • Absolute humidity
    • Mixing ration
    • Air pressure QFE, QFF, QNH
    • Evaporation acc. to Haude, Richter or Wendling
    • Wind-chill
    • Perceivable temperature
    • Sunshine duration
    • Wind velocity component
    • Daily mean temperature acc. to DWD/­German Weather Service (from 3 or 4 values)
    • Flow at weirs acc. to Swiss Standard
    • Heating degree days
    • Sunshine
    • Direct solar radiation
    • Diffuse sky radiation
    • Sunshine duration from daily mean value of global radiation

    Presentation of measuring values

    Graphics

    • Graphic 4 in 4 (four measuring values in four diagrams)
    • Graphic 4 in 1 (four measuring values in one diagram)
    • Diurnal cycle 4 in 1(four time-slice-mean value over one day in four diagrams)
    • Diurnal cycle 4 in 4 (four time-slice-mean values over one day in one diagram)
    • Correlation
    • Wind rose
    • Report

    Lists:

    • 4 channel list (display of four measuring values in a list with date and time)
    • extreme values
    • station list
    • report

    Output of Graphics and Lists:

    Via Windows driver and printer, plotter or in a file

    Data export

    • dBase (dBase IV data bank file)
    • DVWK (special format for precipitation values)
  • Specification

    Compatibility
    Connectable instruments
    all THIES data logger
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10
    Software
    max. stations
    99
    max. components per station
    99
    ASCII - import
    available
    MEVIS data path
    configurable
    automatical data export
    available
    Extentions
    MEVIS viewer
    Lizence protection
    hardware dongle
  • Versions

     
    9.1796.xx.xxx
    Product number 9.1796.50.000
    Software
    Language
    German
    Product number 9.1796.50.001
    Software
    Language
    English
  • Accessories

    No accessories are available for this product.