Ultrasonic Anemometer 2D
Part number: 4.382x.3x.xxx
-
Description
The Ultrasonic Anemometer 2D serves for the 2-dimensional acquisition of the horizontal components of the wind velocity, the wind direction as well as of the acoustic-virtual temperature.
Heated components:
• sensor arms
• ultrasonic transducers
More than 35 different measurement values are available, for ex.:
• Orthogonal wind velocity
vectors (X- and Y-distance)
• Scalar wind velocity
• Wind direction
• Acoustic-virtual temperature
• Acoustic-virtual temperature of the orthogonal measurement distances (X- and Y-distance)
• Standard deviation of the vectorial wind velocity
(X and Y-distance)
• Standard deviation of the scalar wind velocity
• Standard deviation
of the wind direction
• Standard deviation of the acoustic-virtual temperature
• Wind velocity of the gust acc. to WMO
• Wind direction of the gust acc. to WMO
The instrument is especially suitable for the use in the fields of
• Meteorology
• Climatology
• Regenerative energy, wind energy plant
• Traffic engineering, aviation and navigation
• Pollutant dispersal
• Wind alarm devices, building construction and building safety
• Indoor flow measurement
• And in alpine field of application
The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.
The measurement values can be transmitted digitally and/or in analogue form.
The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.
If necessary, the sensor arms are automatically heated in case of critical ambient emperatures. The possibility of malfunction, caused by icing, is minimized.
Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suitable even for the more difficult use in locations where frequently icing is to be expectedSpecification
Wind speedMeasuring range0 ... 85 m/sResolution0.1 m/s (standard)
0.01 m/s (user defined)Accuracy±0.1 m/s rms ( < 5 m/s )
±2 % rms ( 5 ... 85 m/s )Wind directionMeasuring range0 ... 360 °Resolution1 °
1 ° (standard)
< 1 ° (user defined)Accuracy±1 ° @ WS 1 ... 60 m/s
±2 ° @ WS 60 ... 85 m/sVirtual temp.Measuring range-50 ... +80 °CResolution0.1 KAccuracy±0.5 K @ WS < 35 m/sData output digitalInterfaceRS485 / RS422Baudrate1200 Baud ... 921600 BaudData valuesinstant. values, average values, standard deviationOutput range1 per 10 msec up to
1 per 60 secStatus signalsheating, Meas section error, Temperature of meas sectionData output analogWind speed0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 VStromausgangmax. 400 êWind direction0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 VVoltage outputmin. 4000 êResolution16 bitData input analog (alternative)Chanels3Resolution16bitOperating voltageElectronic8 ... 78 V DC or
12 ... 55 V AC / 2.5 WHeating24 V AC/DC, typ 80 WHeatingHeated compontentsSensor arms
Silicon caps of ultrasonic sensorsGeneralBus operationup to 98 sensorsElectr. connection8 pol. connectorMountingon a mast tube 1,5``Housingstainless steel (V4A) AiSi316TiProtectionIP 67DimensionØ 424 mm x 287 mmWeight2.5 kgVersions
Product number 4.3820.32.300Data output digitalBaudrate9600 BaudDuplex modeHalf duplexData telegramno independent data outputData output analogType3 x 0 ... 10 VProduct number 4.3820.32.301Data output digitalBaudrate9600 BaudDuplex modeHalf duplexData telegramno independent data outputData output analogType3 x 0 ... 10 VProduct number 4.3820.31.300Data output digitalBaudrate9600 BaudDuplex modeHalf duplexData telegramno independent data outputData output analogType3 x 0 ... 20 mAProduct number 4.3820.30.340Data output digitalBaudrate9600 BaudDuplex modeFull duplexData telegramVDT-Telegram (Telegram2)Output range10 per 1 secProduct number 4.3826.30.340Data output digitalBaudrate9600 BaudDuplex modeFull duplexData telegramVDT-Telegram (Telegram2)Output range10 per 1 secGeneralSpecial featureFor upside down useProduct number 4.3820.34.398Data output digitalInterfaceRS485 / RS422Baudrate1200 ... 921600 BaudData valuesinstant. values, average values, standard deviationOutput range1 per 10 msec up to
1 per 60secStatus signalsheating, Meas section error, Temperature of meas sectionData output analogWind speed0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 VStromausgangmax. 400 êWind direction0 ... 20 mA
4 ... 20 mA
0 ... 10 V
2 ... 10 VVoltage outputmin. 4000 êResolution16 bitData input analog (alternative)Chanels3Resolution16bitOperating voltageElectronic8 ... 60V DC or
12 ... 42 V AC / 2.5 WHeating24 V AC/DC, typ 240 WGeneralBus operationup to 98 sensorsElectr. connection8 pol. connectorMountingon a mast tube 1,5``Housingstainless steel (V4A) AiSi316TiProtectionIP 65DimensionØ 424 mm x 287 mmWeight2.5 kgProduct number 4.3820.34.318Data output digitalBaudrate9600 BaudDuplex modeHalf duplexData telegramno independent data outputData output analogType3 x 0 ... 10 VAccessories
ProductProduct nameProduct name / Brief description
4.3800.90.000Ultrasonic Bird delfector
Ultrasonic Bird delfector
The Ultrasonic Bird Deflector protects the ultrasonic anemometer against measurement faults, which might be caused by different species of birds.
507245Device to refuse birds
Device to refuse birds
The device to refuse birds shall prevent smaller birds in the distance of the US transformer from sitting on the instrument, thus providing for an undisturbed operation.50775xConnecting cable
Connecting cable
Suitable cable for 4.3820/30/75/80/81
• length: see versions
508396Bird spike
Bird spike
The bird spike prevents bigger birds from resting in the measurement path between the ultrasonic transducers, providing an undisturbed operation.
508696Northring for Ultrasonic anemometer
Northring for Ultrasonic anemometer
The adapter is used for the north alignment of a Ultrasonic anemometer.
9.1700.98.x01Meteo-Online
Meteo-Online
Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/or as text The user has the possibility to place the display-elements free on the screen, and to save them.Further information
This website uses cookies. Some of them are necessary, while others help us to improve this website and your experience.
I agree and can revoke or change my consent at any time with effect for the future.
I agree and can revoke or change my consent at any time with effect for the future.