Ultrasonic Anemometer 3D

Part number: 4.383x.2x.xxx

  • Description

    4.3830.2x.xxx
    The Ultrasonic Anemometer 3D serves for the 3-dimensional acquisition of the horizontal and vertical components of the wind velocity, the wind direction as well as of the acoustic-virtual temperature.

    Heated components:
    • sensor arms
    • ultrasonic transducers
    More than 70 different measurement values are available, for ex.:
    • Wind velocity in X/­Y/­Z-direction
    • Total wind velocity
    • Wind velocity azimuth
    • Wind direction azimuth
    • Wind velocity elevation
    • Wind direction elevation
    • Acoustic-virtual temperature
    • Standard deviation of the wind velocity in X/­Y/­Z-direction
    • Standard deviation of the total wind velocity
    • Standard deviation of the wind velocity azimuth
    • Standard deviation of the wind direction azimuth
    • Standard deviation of the wind direction elevation
    • Standard deviation of the acoustic-virtual temperature
    • Statistic functions such as variance, co-variance, turbulence intensity
    • Wind velocity X/­Y/­Z of the gust acc. to WMO
    • Wind direction of the gust (elevation) acc. to WMO

    The instrument is especially suitable for the use in the fields of
    • Meteorology
    • Climatology
    • Traffic engineering, aviation and navigation
    • Indoor flow measurement
    • And in alpine field of application
    The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.
  • Specification

    Wind speed
    Measuring range
    0 ... 85 m/­s
    Resolution
    0.1 m/­s (standard)
    0.01 m/­s (user defined)
    Accuracy
    ±(0.1 m/­s +1 % ) rms ( 0 ... 35 m/­s )
    ±2 % rms ( 35 ... 65 m/­s )
    ±3 % rms ( 65 ... 85 m/­s )
    Wind direction
    Measuring range
    0 ... 360 ° /­ 540 ° /­ 720 °
    Resolution
    1 ° (standard)
    < 1 ° (user defined)
    Accuracy
    ±1 ° ( 1 ... 35 m/­s )
    ±2 ° ( 35 ... 65 m/­s )
    ±4 ° ( 65 ... 85 m/­s )
    Virtual temp.
    Measuring range
    -50 ... +80 °C
    Resolution
    0.1 K
    Accuracy
    ±0.5 K
    Data output digital
    Interface
    RS485 /­ RS422
    Baudrate
    1200 Baud ... 921600 Baud
    Data values
    instant. values, average values, standard deviation
    Output range
    1 per 10 msec up to
    1 per 60 sec
    Status signals
    heating, Meas section error, Temperature of meas section
    Data output analog
    Measured values
    WS - Vectors VxVyVz
    WS - Azimut, WD - Azimut, WS Elevation
    Wind speed
    0 ... 20 mA;
    4 ... 20 mA;
    0 ... 10 V;
    2 ... 10 V;
    Stromausgang
    max. 400 Ω
    Wind direction
    0 ... 20 mA;
    4 ... 20 mA;
    0 ... 10 V;
    2 ... 10 V;
    Voltage output
    min. 4000 Ω
    Resolution
    16 bit
    Data input analog (alternative)
    Chanels
    3 x 0 ... 10 V
    Resolution
    16 bit
    Operating voltage
    Electronic
    8 ... 78 V DC or
    12 ... 55 V AC /­ 2.5 W
    Heating
    24 V AC/­DC, typ 150 W
    General
    Bus operation
    up to 98 sensors
    Electr. connection
    8 pol. connector
    Mounting
    on mast tube 1,5``
    Housing
    stainless steel (V4A) AiSi316Ti
    Protection
    IP 67
    Dimension
    600 mm x 300 mm
    Weight
    3.4 kg
  • Versions

     
    4.3830.2x.xxx
    Product number 4.3830.20.340
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Full duplex
    Data telegram
    VDT-Telegram (Telegram2)
    Output range
    10 per 1 sec
    Product number 4.3830.22.300
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Half duplex
    Data telegram
    no independent data output
    Data output analog
    Type
    3 x 0 ... 10 V; Vx, Vy, Vz
    Product number 4.3830.20.300
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Full duplex
    Data telegram
    no independent telegram output
    Product number 4.3830.21.310
    Data output digital
    Baudrate
    9600 Baud
    Duplex mode
    Half duplex
    Data telegram
    no independent data output
    Data output analog
    Type
    3 x 4 ... 20 mA
  • Accessories

    Product
    Product name
    Product name / Brief description

    Connecting cable

    50775x

    Connecting cable


    Suitable cable for 4.3820/­30/­75/­80/­81

    • length: see versions
     
    General
    Cable length
    see versions
    Cable
    PUR 4 x 0,75 +2x2x0,14 mm²
    509619

    Northring for Ultrasonic anemometer

    508696

    Northring for Ultrasonic anemometer


    The adapter is used for the north alignment of a Ultrasonic anemometer.
     
    General
    Length
    90 mm
    Material
    Alluminum anodized ( AlMgSi1 )
    Weight
    0.4 kg
    Mounting
    for mast Ø 50 mm
    for sensor Ø 50 mm
    9.1700.98.x0x

    Meteo-Online

    9.1700.98.x01

    Meteo-Online


    Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/­or as text The user has the possibility to place the display-elements free on the screen, and to save them.
     
    Data display
    Monitor - display
    - Values
    - Diagrams
    - Tables
    - Windrose
    - Time
    - Date
    Compatibility
    Connectable instruments
    - US-Anemometer
    - Datalogger
    - Clima Sensor
    - Weather station WSC11
    - Wind display
    - etc.
    System requirements
    PC mit
    - Prozessor > 1 GHz
    - RAM > 1 GB
    Operating system
    - Windows 2003 SP2
    - Windows Server 2008
    - Windows 7
    - Windows Server 2008 R2
    - Windows 7 SP1
    - Windows Server 2008 R2 SP1
    - Windows 8
    - Windows 10