Datalogger DLU
Part number: 9.1711.10.0x0
-
The datalogger records measuring values via two serial interfaces RS485/422, and via integrated analogue and digital input channels. The serial interfaces are designed for the connection of sensors with MODBUS-RTU interface, and for sensors with THIES data protocol. It is possible to connect up to 32 devices to one bus. The analogue inputs serve for connecting a humidity temperature sensor with PT100, and voltage output, and up to three sensors with voltage output 0 … 10 V. The digital inputs support the direct connection of a wind direction transmitter with synchronous-serial output, and two precipitation meters with pulse output.
There is a pixel touch display 320 x 240 available for diagnosis and startup. It serves for displaying instantaneous and archival values. Simple parametrizations can be carried out.
The data query occurs via Ethernet ( only with 9.1711.10.010 ), or via one of the two interfaces RS485/422. All interfaces support the data query in ASCII format. The data can be enquired via Ethernet and WLAN additionally in binary format and SFTP.
The 9.1711.10.010 contains an internal WEB server for displaying the instantaneous and archival values, and for configuration. The configuration can be carried out in addition also „offline” via Windows tool.
The datalogger DLU is designed for indoor installation.
Outdoor application requires an additional cover housing with respective degree of protection
-
Analogue data sampling |
A/D - converter | 16 bit |
Accuracy | ±0.1 % of meas. range |
Noice ratio | yes @ 50Hz |
Multifunction inputs |
Quantity | 3 |
Function | 3 x 0 ... 100 mV 3 x 0 ... 1 V 3 x 0 ... 10 V 3 x 0 ... 20 mA 3 x 4 ... 20 mA |
Wind speed |
Electrical input | 2 x Impulses ( altrnative to precipitation ) |
Precipitation |
Electrical input | 2 x impulses (0 ... 5 V) |
Resolution | 0.1 mm |
Temperature |
Electrical input | 1 x PT100 |
Measuring range | -40 ... +70 °C |
Accuracy | ±0,1 K |
Rel. Humidity |
Electrical input | 1 x 0.02 ... 1 V |
Measuring range | 2 ... 100 % rel. h. |
Accuracy | ± 0.001 % rel. h. |
Serial interfaces |
Quantity | 3 |
Configuration | USB |
Supported devices | COM1, COM2: LPM, US2D, US2D Compact, Clima Sensor US, WSC11 |
Function | COM1, COM2: data access, sensor connection, instantaneous values USB: Configuration, data access |
Data output digital |
Interface | COM1: RS485 HD or FD COM2: RS485 HD or FD |
Data management |
Measurement cycle | 1 ... 3600 s |
Memory cycle | 1 ... 60 min |
Memory capacity | 64 MByte |
Number data records | depending on configuration Example: 276192 ( 14 channels ) |
Output of archive values | serial via COM1, COM2, USB (ASCII - formatted) Export to SD - card (ASCII - formatted) |
Operating voltage |
Electronic | 24 V DC or 24 V AC |
Current consumption | min. 1.7 mA max. 32 mA |
Battery connection | for 12 V battery |
Internal battery charger | 15 ... 18 V / max. 20 W |
General |
Ambient temp. | -20 ... +70 °C |
Electr. connection | clamp |
Dosplay | 2,4 " Colour - Touch - Display 320 x 240 Pixel |
Mounting | DIN mounting |
Protection | IP 20 |
Dimension | 157 x 86 x 58.5 mm |
Weight | 0.7 kg |
-
Product number 9.1711.10.000
Serial interfaces |
Ethernet connection | no |
Product number 9.1711.10.010
Serial interfaces |
Ethernet connection | yes |
Ethernet |
supported functions | SFTP, TELNET, WEB-Server |
-
Product
Product name
Product name / Brief description
Power supply Unit
Power supply for DIN mounting rail
primary:
• 85 ... 264V AC
secundary:
• 24 V DC / 60 W
Operating voltage |
Primary | 85 ... 230 V AC |
Secundary | 24 V DC / 60 W |
Electrical connection |
Series terminals | 4 |
General |
Housing | plastic |
Protection | IP 20 |
Dimension | ca. 35 x 90 x 84 mm |
Weight | 0.2 kg |
Power supply Unit
Power supply for DIN mounting rail
primary:
• 85 ... 264V AC
secundary:
• 24 V DC / 240 W
Operating voltage |
Primary | 85 ... 230 V AC |
Secundary | 24 V DC / 240 W |
Electrical connection |
Series terminals | 4 |
General |
Housing | plastic |
Protection | IP 20 |
Dimension | ca. 45 x 230 x 125 mm |
Weight | 0.66 kg |
Meteo-Online
Meteo-Online is a software for detecting, filing, and displaying data of meteorological measuring instruments. The display of the data is carried out graphically as diagram and/or as text The user has the possibility to place the display-elements free on the screen, and to save them.
Data display |
Monitor - display | - Values - Diagrams - Tables - Windrose - Time - Date |
Compatibility |
Connectable instruments | - US-Anemometer - Datalogger - Clima Sensor - Weather station WSC11 - Wind display - etc. |
System requirements | PC mit - Prozessor > 1 GHz - RAM > 1 GB |
Operating system | - Windows 2003 SP2 - Windows Server 2008 - Windows 7 - Windows Server 2008 R2 - Windows 7 SP1 - Windows Server 2008 R2 SP1 - Windows 8 - Windows 10 |
Mevis Light
PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
Compatibility |
Connectable instruments | all THIES data logger |
System requirements | PC mit - Prozessor > 1 GHz - RAM > 1 GB |
Operating system | - Windows 2003 SP2 - Windows Server 2008 - Windows 7 - Windows Server 2008 R2 - Windows 7 SP1 - Windows Server 2008 R2 SP1 - Windows 8 - Windows 10 |
Software |
max. stations | 5 |
max. components per station | 30 |
ASCII - import | not available |
MEVIS data path | fix, not changeble |
automatical data export | only manually via dialog |
Extentions | no |
Lizence protection | intalledUser |
Mevis Full Version
PC- program for automatically data request of THIES- data logger with archiving, vdata visualisation and evaluation
Compatibility |
Connectable instruments | all THIES data logger |
System requirements | PC mit - Prozessor > 1 GHz - RAM > 1 GB |
Operating system | - Windows 2003 SP2 - Windows Server 2008 - Windows 7 - Windows Server 2008 R2 - Windows 7 SP1 - Windows Server 2008 R2 SP1 - Windows 8 - Windows 10 |
Software |
max. stations | 99 |
max. components per station | 99 |
ASCII - import | available |
MEVIS data path | configurable |
automatical data export | available |
Extentions | MEVIS viewer |
Lizence protection | hardware dongle |
-