Part number: 4.3351.00.xxx
Special characters are a defined and optimised, dynamic behaviour also at high turbulence intensity, minimal over-speeding, and a low starting value. The measuring value is available at the output as analogue signal and as rectangular digital signal.
For winter operation the instrument (4 .3351 .00 .xxx) is equipped with an electronically regulated heating.
4.3352.00.000

Specification


Part number: 4.3351.00.xxx
 
4.3352.00.000
Wind speed
Measuring range
0 ... 75 m/s
Accuracy
< 1 % of meas. value ( 0.3 ... 50 m/s )
or < ±0.2 m/s
Linearity
r > 0.99999 ( 4 ... 20 m/s )
Delay distance
< 3 m ( aac. to ASTM D 5096-96 )
Data output digital
Frequency
1082 Hz at 50 m/s
Operating voltage
Electronic
3.3 ... 48 V DC
130 µA from 3,3 ... 15 V
180 µA > 15 V
Heating
24 V AC/DC, max 25 W
General
Ambient temp.
-50 ... +80 °C
Electr. connection
8 pol. plug connection
Mounting
onto mast tube Ø 1``
Protection
IP 55
Survival speed
80 m/s ( min. 30 minutes )
Weight
0.5 kg
Fixing boring
Ø 35 x 25 mm
Matirial housing
aluminium, anodised
Material cup star
carbon-fiber glass reinforced

Versions


As per 4.3351.00.xxx, but:
 
4.3352.00.000
Product number 4.3351.00.140
Data output digital
Sink Output
1 ... 250 mA
Source Output
1 ... 100 mA
Data output analog
Wind speed
0 ... 20 mA ( 0 ... 75 m/s )
Product number 4.3351.00.141
Data output digital
Sink Output
1 ... 250 mA
Source Output
1 ... 100 mA
Data output analog
Wind speed
4 ... 20 mA ( 0 ... 75 m/s )
Product number 4.3351.00.161
Data output digital
Sink Output
1 ... 250 mA
Source Output
1 ... 100 mA
Data output analog
Wind speed
0 ... 10 V ( 0 ... 75 m/s )
Product number 4.3351.00.173
Data output digital
Sink Output
1 ... 250 mA
Source Output
1 ... 100 mA
Data output analog
Wind speed
0 ... 5 V ( 0 ... 75 m/s )

Accessories

 
Product
Product name
Product name / Brief description
4.3174.00.000

Traverse for Wind Transmitters "First Class"

4.3174.00.000

Traverse for Wind Transmitters "First Class"


For mounting the wind speed transmitter and wind direction transmitter jointly onto a mast.
 
General
Height
0.76 m
Mounting
on mast tube Ø 1,5``
Material
aluminium, anodised (AlMgSi0.5)
Sensor distance horizontal
0.6 m
Sensor distance vertikal
0.2 m
Weight
3 kg
Fixing boring
Ø 34 mm for First Class wind sensors
4.3184.01.000

Hanger 1m First Class

4.3184.01.000

Hanger 1m First Class


The hanger is used for the lateral mounting of a wind transmitter, First Class type, onto a mast
 
General
Length
1 m
Mounting
at mast tube Ø 40 ... 80 mm
Material
aluminium (AlMgSi0.5)
Weight
1.5 kg
Fixing boring
Ø 34 mm

Further information

 
 
 
Certificates
FirstClass 4.3351.xx.xxx Classification
 

Contact
Phone: +49 551 / 79001-0
Fax: +49 551 / 79001-65
info@thiesclima.com

Inquiry / Message

Please use the form below for your inquiry or message.
 
 
Wind Transmitter "First Class" Advanced (4.3351.00.xxx)
THE WORLD OF WEATHER DATA
HumidityPrecipitationWindTemperatureMiscellaneous-DevicesRadiationAir-pressureCompany

WE ARE MEMBER OF:

Adolf Thies GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Phone +49 551 / 79001-0 Fax +49 551 / 79001-65 info@thiesclima.com www.thiesclima.com
This website uses cookies. In these, however, no personal contents are stored. By further entering this website you consent to our use of cookies. Further Information
UNDERSTOOD