Wind speed | |
Measuring range | 0 ... 75 m/s |
Resolution | 0.1 m/s |
Accuracy | ±0.2 m/s rms ( < 5 m/s ) ±2 % rms ( 5 m/s ... 60 m/s ) |
Wind direction | |
Measuring range | 0 ... 360 ° |
Resolution | 0.1 ° |
Accuracy | ±2 ° WS > 1 m/s |
Virtual temp. | |
Measuring range | -50 ... +70 °C |
Resolution | 0.1 K |
Accuracy | ±2 K |
Data output digital | |
Interface | PROFINET V2.42 CLASS B, PROFIsafe V2.6.1, Webinterface |
Data values | WG, WR, VT, LD, DATA QUALITY, STATUS |
Output range | 10-Mbit/s, 100-Mbit/s |
Operating voltage | |
Electronic | U: 17 ... 48V DC ± 10% P: typ. 4,5W, max. 6W SELV or PLEV |
Heating | U: 48V DC ± 10% P: typ. 300 W SELV or PLEV |
Heating | |
Heated compontents | bottom plate, cover plate, ultrasonic transducers |
Icing resistance | Acc. to MIL-STD-810G, METHOD 521.3, 2008/10 |
General | |
Firmware update | Firmware update via Ethernet |
Predictive Maintenance Indicator | Yes |
Electr. connection | 8 pol. connector |
Mounting | e.g. Mast tube Ø 50mm |
Housing | AL, hard-snodized |
Protection | IP 68 |
Dimension | Ø 200 mm x 144 mm |
Weight | approx. 2 kg |
Air pressure | |
Measuring range | 300 ... 1100 hPa |
Resolution | 0.1 hPa |
Accuracy | ± 0.25hPa @ 700 ... 1050hPa and +25 ...+40 °C ± 2.0hPa @ 300 ... 1100hPa, -40...+60 °C and activated heating |
Long-term stability | < ± 1hPa per year |